Effect of Gas Recycle Rate on Net Plant Efficiency of A SPOC Power Plant

Autori

  • Zijuan Gao North China Electric Power University, China

DOI:

https://doi.org/10.26821/IJSHRE.13.04.2025.130304

Cuvinte cheie:

Staged, Pressurized Oxy-Combustion, supercritical CO2 cycle, flue gas recycle, Simulation

Rezumat

Oxy-combustion technology is a promising near-zero carbon emission technology, however, its low efficiency and low economy limit its wide application to some extent. In this paper, a new thermal power system is proposed, which is a staged, pressurized oxy-combustion (SPOC) coupled with sCO2 cycle coal-fired power generation system. The system was constructed and simulated by Aspen Plus v12, and the influence of flue gas recycle (FGR) ratio on system efficiency was studied. The research shows that: in the range of 10% - 55.53%, the net efficiency of the system gradually decreases with the increase of the recycle ratio. When the recycle rate is 50%, the efficiency decreases by 3.5% compared with the condition without gas recycle. However, the relationship between the net efficiency and the recycle ratio is not linear. The net efficiency is greatly lost when recycle ratio is higher than 27.8%, and less than 27.8%, the net efficiency loss is less than 1 percentage point.

Referințe

LIU S, LI H Y, ZHANG K, LAU H C. Techno-economic analysis of using carbon capture and storage (CCS) in decarbonizing China's coal-fired power plants[J]. Journal of Cleaner Production, 2022, 351.

YIN C G; YAN J Y. Oxy-fuel combustion of pulverized fuels: Combustion fundamentals and modeling[J]. Applied Energy, 2016, 162:742-762.

AKSHAY GOPAN; BENJAMIN M. KUMFER; JEFFREY PHILLIPS et, al. Process design and performance analysis of a Staged, Pressurized Oxy-Combustion (SPOC) power plant for carbon capture[J]. Applied Energy, 2014, 125: 179-188,

AKSHAY GOPAN; BENJAMIN M. KUMFER; RICHARD L. AXELBAUM. Effect of operating pressure and fuel moisture on net plant efficiency of a staged, pressurized oxy-combustion power plant[J]. International Journal of Greenhouse Gas Control, 2015, 39: 390-396.

XU J L; WANG X; SUN E H; LI M J. Economic comparison between sCO2 power cycle and water-steam Rankine cycle for coal-fired power generation system[J]. Energy Conversion and Management, 2021, 238

XU J L; LIU C; SUN E H; XIE J; LI MJ; YANG YP; LIU JZ. Perspective of S−CO2 power cycles[J]. Energy, 2019, 186.